SOLUÇÕES INOVADORAS
DE SUPORTAGEM

Aplicação

Connecting element to fix Channel MS 27 to beam- and girder structures. Fixing to the channel regardless the orientation of channel opening or slotted side .

Configuração

Completely pre-assembled with U-Bolt, Bracket and Flange Nut.

Instalação

To be used in pairs only.
Tightening torque: 20 Nm
Length calculation = Beam/Girder flange thickness + min. 2 x 50 mm overhang.

Dados Técnicos

Max. perm. load tension:
2.0 kN per Beam Clamp
Material:
Steel, electro-galvanised
Typmax. Flansch-
dicke [mm]
GewindeG
[kg]
Verp.
[Stück]
Artikel-
Nr.
27 - M825M80,2920 195864